| The platform consists of three decks |
|
The upper deck Composed of a living quarter with 5 sleeping rooms , a living room and kitchen. It contains also the control room, the electric power transformers and the battery room,The main dec Which contains the necessary equipment used for operating the platform and the ethylene storage tanks,It contains the following : Two unloading arms (one stand by) for unloading Ethylene from tankers to storage tanks. The discharge capacity through the arm is 170 ton / hr of liquid Ethylene and made of stainless steel. Ethylene storage Tanks That is 3 horizontal cylindrical storage tanks fabricated from 9% nickel steel to suit the cryogenic storing conditions of Ethylene(-103oC ) with capacity of 3000 MT. The tanks are insulated with 400 mm perlite. Layer with an inter space between the tank wall and that of perlite containing dry nitrogen gas(-72C) the whole tank is enveloped with 6 mm steel casing. One submerged pump is erected in each tank, The Ethylene liquifaction unit Any vaporized ethylene gas from the tanks is reliquified by this unit Cooling rate: 6500 kcal/hr which is equivalent to 575 kg/hr liquid ethylene. |
| Ethylene Vaporization unit |
| Capacity: 7500 kg ethylene /h. The ethylene being vaporized in this unit is pumped to the pipeline to Amryia site at 7.5 ton /hr and pressure 12kg / cm2, Air production unit m3/ h),The Inert gas production unit for purging purposes capacity 450 m3/ hr air,Nitrogen unit(21 m3/hr) Electrical Power generation units there are 3 power generation units of 0.8 mw each–one is working the second lies as Stand by and the third is any used in emergency cases Antifreeze unit. The cellar deck This floor contains Storage tanks 70 m3 capacity : Drinking water tank 70 m3 capacity : gas oil tank 12.5 m3 capacity : nitrogen gas 50 m3 capacity : air tank Sodium hypochlorite production unit : Of a capacity 5 m3/hr which is used for prevention of the marine growth and microorganism's scales inside the water fire lines of the fire loops & cooling water system. |
| Fire Fighting System |
| Fire fighting system Is designed in accordance with N.F.P. Codes and specifications as follows : Two diesel fire pumps used for supplying water to Fire system , Water spraying system , out door water , hydrant system , powder system , hallon system , and outomatic fire alarm system provideds with detection system furnished with smoke detectors, Heat detectors, u.v detectors and push buttons. REMARK : Platform was stopped activity since the year 2000 due production of ethylene locallyPlatform is in a standby to any new operation activity. |